Page/Seite
38 / 45
BG 66
d
Move
Version 02-09-2020
6.9.1 Circuit Diagram for BG 66 dMove Motors
6.9.1 Schaltplan für BG 66 dMove Motors
1
2
3
4
5
6
7
8
9
10
11
12
4
5
4
5
A
B
C
IN 0
IN 1
IN 2
IN 3
CAN high (IO version)
CAN high (IO version)
AI +
AI -
U Logic
OUT 1
OUT 2
N. C.
U-POWER
GND Logic + POWER
BALLAST (on request)
BG 66 d Move
...to next motors
connect housing to machine earth
for EMC shielding
* MCB: Miniature circuit breaker, use DC-suitable UL listed inverse-time circuit breakers.
Select the rated current of the circuit breaker according to the used wire diameters.
...to next motors
soft start circuit
(if not otherwise
provided by
power supply)
2,2 Ohm
> 50 W
2,2 Ohm
≥
50 W
ballast
circut on
request
2x MCB*
B-type 16 A
MCB*
A-type 1 A
example:
connection of a switch/sensor
U+
U+
GND-
GND-
from
power supply
from logic /PLC
power supply
from control unit (CO version)
to next device (CO version)
M16, 12+3 in Power- and
Logic connector
M12 CAN
Male con.
M12 CAN
Female con.
CAN H
CAN L
CAN H
CAN L
8 A
time
lag
fuse
example:
signal lamp, actor
M
~
-