MegaRAC® G4 User’s Guide
48
Changing the Current Default Target:
The command to change the target is cd.
Æ
cd /system1
Æ
cd ..
Æ
cd /system1/cpu1/sensor1
Æ
cd ../../..
How to get help
The command to get help is to type: help. Associate help with the command name and
the help for that command will show up.
Æ
help show
Æ
show –help
How to check values of sensors or targets
The command to use is show and then we have to associate a target and the property with
it.
Æ
show /sensor1
This will show the values associated with the sensor1.
To see one particular value of the target we have to use the property keyword for the
command.
Æ
show –display properties = IP /nic1
To see one or more properties for a particular target we can use multiple properties.
Æ
show –display properties = (IP, MAC) /nic1
How to set the values of the sensor or targets
The “SET” command is used to modify the values of the targets.
Æ
set /nic1 ip=10.0.0.23