background image

ADJ Products, LLC  -  www.adj.com  - Inno Beam LED Instruction Manual Page 7

ADJ Products, LLC  -  www.adj.com  - Inno Beam LED Instruction Manual Page 8

Power Supply:

 The ADJ Inno Beam LED contains a automatic volt-

age switch, which will auto sense the voltage when it is plugged into 

a power source. With this switch there is no need to worry about the 

correct power voltage, this unit can be plugged in anywhere.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 

communication between intelligent fixtures and controllers. A  DMX 

controller sends DMX data instructions from the controller to the fix-

ture. DMX data is sent as serial data that travels from fixture to fixture 

via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 

fixtures (most controllers only have a DATA “OUT” terminal). 

DMX Linking: 

DMX  is  a  language  allowing  all  makes  and  models 

of different manufactures to be linked together and operate from a 

single  controller,  as  long  as  all  fixtures and  the  controller  are DMX 

compliant.  To ensure proper DMX data transmission, when using 

several DMX fixtures try to use the shortest cable path possible. The 

order in which fixtures are connected in a DMX line does not influence 

the DMX addressing. For example; a fixture assigned a DMX address 

of 1 may be placed anywhere in a DMX line, at the beginning, at the 

end, or anywhere in the middle. Therefore, the first fixture controlled 

by the controller could be the last fixture in the chain. When a fixture 

is assigned a DMX address of 1, the DMX controller knows to send 

DATA assigned to address 1 to that unit, no matter where it is located 

in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave 

Operation): 

The Inno Beam LED can be controlled via DMX-512 pro-

tocol. The Inno Beam LED has 2 DMX modes. The DMX address is 

set  electronically  using  the  controls  on  the  front 

panel of the unit. Your unit and your DMX control-

ler  require  a  approved  DMX-512  110  Ohm  Data 

cable for data input and data output (Figure 1). We 

recommend  Accu-Cable  DMX  cables.  If  you  are 

making your own cables, be sure to use standard 

110-120 Ohm shielded cable  (This  cable  may  be 

purchased  at  almost  all  professional  sound  and 

lighting stores). Your cables should be made with 

 Inno Beam LED                                                       Set Up

Figure 1

Screw one clamp via a M12 screw and nut onto the Omega 

holder. Insert the quick-lock fasteners of the Omega holder 

into the respective holes on the bottom of the Inno Beam LED. 

Tighten the quick-lock fasteners fully clockwise. Pull the safety-

cable through the hole on the bottom of the base and over the 

trussing system or a safe fixation spot. Insert the end in the 

carabine and tighten the safety screw.

NOTICE:

 The suitable enviromental temperature for this light-

ing fixture is between -25˚ C to 45˚ C. Do not place this lighting 

fixture in an enviroment where the temperatures are under or 

above the temperatures stated above. This will allow the fixture 

to run at its best and help prolong the fixture life. 

 Inno Beam LED    

                                      Mounting

Summary of Contents for Inno Color Beam LED

Page 1: ...t names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipment building and...

Page 2: ...tain important safety information regarding the use and maintenance of this unit Please keep this manual with the unit for future reference Inno Beam LED General Instructions Inno Beam LED General Inf...

Page 3: ...be situated away from heat sources such as radiators heat registers stoves or other appliances including amplifiers that produce heat The fixture should be serviced by qualified service personnel when...

Page 4: ...refore the first fixture controlled by the controller could be the last fixture in the chain When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 t...

Page 5: ...12 DMX DMX COMMON 1 2 3 Termination reduces signal errors and avoids signal transmission problems and interference It is always advisable to connect a DMX terminal Resistance 120 Ohm 1 4 W between PIN...

Page 6: ...2 X will now be displayed X represents the displayed address Press the UP or DOWN buttons to find your desired address 3 Press ENTER to confirm and then press and hold the MENU button for at least thr...

Page 7: ...o adjust the sensitivity level The sensitivity level can be adjusted between 0 the lowest and 100 most sensitive Inno Beam LED System Menu 2 Show X will now be displayed X representing a number betwee...

Page 8: ...ght on again 3 Press ENTER to confirm Dimmer Calibrat With this function you can set the output intensity 1 Press the MENU button until Dimmer Calibrat is displayed press ENTER 2 A number between 50 1...

Page 9: ...Press the MENU button for one second to exit Tilt Offset Adjustment of the tilt home position 1 Press the ENTER button for at least 3 seconds then press the UP or DOWN buttons so that Tilt Offset is...

Page 10: ...uttons so that ON is displayed and press ENTER 2 The sound sensitivity can be adjusted by pressing the MENU button until Sound Sense is displayed Press ENTER and use the UP and DOWN buttons to adjust...

Page 11: ...ller not included may be used to con trol different functions including blackout Stand By Blackout the unit Function 1 Sync Strobe 2 Async strobe 3 Sound Strobe Show 1 4 1 Press to select color 2 Hold...

Page 12: ...60 PRISM INDEXING 128 189 COUNTER CLOCKWISE ROTATION FAST SLOW 190 193 STOP 194 255 CLOCKWISE ROTATION SLOW FAST 7 SHUTTER 0 7 OFF 8 15 OPEN 16 131 STROBING SLOW FAST 132 139 OPEN 140 181 SLOW OPEN FA...

Page 13: ...NGE 100 109 NOTHING 110 119 BLACKOUT W GOBO CHANGE 120 199 NOTHING 200 209 RESET ALL 210 255 NOTHING ADJ Products LLC www adj com Inno Beam LED Instruction Manual Page 26 ADJ Products LLC www adj com...

Page 14: ...Use a brush to wipe down the cooling vents and fan grill 3 Clean the external optics with glass cleaner and a soft cloth every 20 days 4 Clean the internal optics with glass cleaner and a soft cloth...

Page 15: ...ll expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the...

Page 16: ...e DMX 12 DMX Channels 14 DMX Channels Colors 8 White Gobos 4 4 Spots Sound Active Yes Working Position Any Safe Secure Position Warranty 2 Year 730 days ADJ Products LLC 6122 S Eastern Ave Los Angeles...