20 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786
Tel: (860) 585-1254 Fax: (860) 584-1973 http://www.amci.com
101
TASK 2
S
ET
THE
IP A
DDRESS
AND
P
ROTOCOL
2.1 Determine the Best Method for Setting the IP Address
There are three methods for setting the IP address on an SMD23E2 or SMD24E2. Table T2.1 below outlines
the available methods and when you can use them.
Table T2.1 Methods for Setting the IP Address
There is a MAC address label on each SMD23E2 and SMD24E2 which has a writable surface.
There is room on the label for writing the programmed IP address of the unit. It is a best prac-
tice to use this label to document the IP address of the unit in case it is ever repurposed.
When using EtherNet/IP, the SMD23E2 and SMD24E2 units also supports the DHCP proto-
col. You will need an EtherNet/IP DHCP server, such as the one available from Rockwell
Automation, in order to use this protocol. The AMCI Net Configurator utility offers the same
functionality and should be used unless your company policy prevents you from installing
third party utilities.
2.2a Use Factory Default Settings
The factory default address for the SMD23E2 and SMD24E2 units is 192.168.0.50, with a subnet mask of
255.255.255.0. The easiest way to verify this address is with the ping command as described in
which starts on page 89.
https://www.wireshark.org/
) can be used to determine the address of the driver.
Task Complete
This section is intended for the engineer or technician responsible for setting the
IP address of an AMCI SMD23E2 or SMD24E2.
Method
Restrictions
Section
1) The machine must use 192.168.0.xxx subnet.
2) The 192.168.0.50 address must be available.
No restrictions on use. This is the preferred method.
The internal webserver can be used to set the
SMD23E2 or SMD24E2 to any IPv4 address. The
IP address and protocol will be stored in nonvolatile
memory and used on subsequent power-ups.
Unit must be initially configured for EtherNet/IP.
The software can be used to set the SMD23E2 or
SMD24E2 to any IPv4 address and protocol. The IP
address and protocol choice will be stored in non-
volatile memory and used on subsequent power-ups.
Summary of Contents for SMD23E2 Series
Page 10: ...ABOUT THIS MANUAL SMD23E2 and SMD24E2 User Manual ADVANCED MICRO CONTROLS INC 10 Notes...
Page 44: ...MOTION CONTROL SMD23E2 and SMD24E2 User Manual ADVANCED MICRO CONTROLS INC 44 Notes...
Page 54: ...CALCULATING MOVE PROFILES SMD23E2 and SMD24E2 User Manual ADVANCED MICRO CONTROLS INC 54 Notes...
Page 88: ...COMMAND MODE DATA FORMAT SMD23E2 and SMD24E2 User Manual ADVANCED MICRO CONTROLS INC 88 Notes...
Page 128: ...MODBUS TCP CONFIGURATION SMD23E2 and SMD24E2 User Manual ADVANCED MICRO CONTROLS INC 128 Notes...
Page 134: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...