SMD23E2 and SMD24E2 User Manual
ADVANCED MICRO CONTROLS INC.
108
2.2c Use the AMCI Net Configurator Utility (continued)
2.2c.8 Set the IP Address, Subnet Mask, and Default Gateway
Enter your desired values into the IP Address, Subnet Mask, and Default Gateway fields.
The Default Gateway setting is not optional! In order to comply with the ODVA specification,
it must be set to a valid address on the chosen subnet. Because the Default Gateway is often
not used in device level networks, if you do not have a required value for it, AMCI suggests
setting the Default Gateway to the IP address of your host controller.
2.2c.9 Set the Communications Protocol
The factory default protocol for the SMD23E2 and SMD24E2 is EtherNet/IP. In order to use the Modbus TCP
or PROFINET protocols, simply click on the appropriate button.
2.2c.10 Write the New IP Address to the SMD23E2 or SMD24E2
Click on the [Set IP Address] button. If there is an error in the settings, the utility will tell you what is wrong.
Once they are all correct, the utility will write the new IP address settings to the unit. These settings are auto-
matically saved to nonvolatile memory.
2.2c.11 Remove Power from the SMD23E2 or SMD24E2
The new IP address will not be used until power to the unit has been cycled.
Task Complete
Summary of Contents for SMD23E2 Series
Page 10: ...ABOUT THIS MANUAL SMD23E2 and SMD24E2 User Manual ADVANCED MICRO CONTROLS INC 10 Notes...
Page 44: ...MOTION CONTROL SMD23E2 and SMD24E2 User Manual ADVANCED MICRO CONTROLS INC 44 Notes...
Page 54: ...CALCULATING MOVE PROFILES SMD23E2 and SMD24E2 User Manual ADVANCED MICRO CONTROLS INC 54 Notes...
Page 88: ...COMMAND MODE DATA FORMAT SMD23E2 and SMD24E2 User Manual ADVANCED MICRO CONTROLS INC 88 Notes...
Page 128: ...MODBUS TCP CONFIGURATION SMD23E2 and SMD24E2 User Manual ADVANCED MICRO CONTROLS INC 128 Notes...
Page 134: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...