background image

EN

3. Explanation of Symbols Used

Symbols for 
the aView

Indication

Symbols for 
the aView

Indication

Consult Instruction 
for Use.

Date of Manufacture,  
followed by YYYY-MM-DD.

Caution.

Manufacturer.

%

Humidity limitation: 
relative humidity 
between 30 and  
85% in operating 
environment.

CE mark. The product  
complies with the EU  
Council directive concerning 
Medical Devices 93/42/EEC

Atmospheric  
pressure limitation: 
between 80 and 109 
kPa in operating  
environment

Waste Bin symbol,  
indicating that waste  
must be collected according 
to local regulation and  
collection schemes for  
disposal of batteries.

Connection to  
external monitor.

Waste Bin symbol,  
indicating that waste must 
be collected according to 
local regulation and  
collection schemes for  
disposal of electronic and 
electrical waste (WEEE).

Direct current.

Li-ion

Battery type Lithium ion. 
Only applicable for the  
battery inside the aView.

Alternating current.

Re-chargeable battery.  
Only applicable for the  
battery inside the aView.

IP30

Protection against 
solid objects.

Only for indoor use.

Lot Number,  
Batch Code.

Tested to comply with  
FCC Standards - Medical 
Equipment.

Reference Number.

2.3. aView Parts

No.

Part

Function

Material

1

Monitor Casing

-

PC / ABS
Rubber

2

Touch Screen

Displays the image 
from the Ambu  
visualization device 
and a touch screen 
interface.

PET / Glass

3

Stand

To place the display 
on a solid surface.

ZDC3

4

Connection  
for Ambu®  
visualization 
devices

Power supply and 
data connection
Protected by a  
rubber cover.

PC / ABS
Rubber

5

Power 

Power inlet for 
charging aView.
Protected by a  
rubber cover.

Rubber

6

Input/output 
connections

JACK connector  
(video-out) and  
USB port.

-

7

Power button

Push button for 
power ON before 
procedure and 
power OFF after 
procedure.

Rubber

8

Docking  
connector

For future use.

-

9

Power supply

Powers the system
Power cord with 
country-specific plug.

PC 
PVC

10

Hexagonal key 

To tighten the bolt 
on the bracket.

CrV

11

Bracket

Secures the monitor 
to e.g. an IV pole.

POM

12

Pouch hook

Slide the hook 
through the 3 holes 
on the bracket. It can 
now be used to hold 
visualization device 
pouches with a hole 
in top corner for easy 
storage before and 
during use.

PAA

13

Adapter cable

For the composite 
video-out interface 
(see no. 6).

PE/PVC

Abbreviations: PC (Polycarbonate), PE (Polyethylene), ABS (Acrylonitrile Butadiene Styrene), 
ZDC3 (Zinc alloy), PVC (Polyvinylchloride), POM (Polyoxymethylene), PAA (Polyarylamide),  
CrV (Chrome Vanadium)

13

10

9

12

11

8

7

6

5

4

1

3

2

6

7

Summary of Contents for aView JANUS2-W08-R10

Page 1: ...For use by trained clinicians physicians only For in hospital use For use with Ambu visualization devices Further instruction details are available online www ambu com Instruction for Use Ambu aView...

Page 2: ...5b aScope 2 aScope 3 aScope 4 Broncho 6 Ambu is a registered trademark and aScope and aView are trademarks of Ambu A S Pat Pending Contents Page English Instruction for Use 4 17 Deutsch Bedienungsanl...

Page 3: ...itor 1 1 Intended Use The aViewTM monitor is a non sterile reusable digital monitor intended to display live imaging data from Ambu visualisation devices 1 2 Warnings and Cautions Failure to observe t...

Page 4: ...Reference Number 2 3 aView Parts No Part Function Material 1 Monitor Casing PC ABS Rubber 2 Touch Screen Displays the image from the Ambu visualization device and a touch screen interface PET Glass 3...

Page 5: ...INMETRO Certificate Medical Electrical Equipment ABNT NBR IEC 60601 1 ABNT NBR IEC 60601 1 2 ABNT NBR IEC 60601 2 18 4 Use of aView Numbers in gray circles below refer to illustrations on page 2 4 1 P...

Page 6: ...nsequences by the reprocessor to ensure that the device continues to fulfil its intended purpose Clean and disinfect the aView according to good medical practice using one of the procedures below Clea...

Page 7: ...w file management tab Return to live image by pressing the blue Live image tab or restart aView by pressing the power button for at least 2 seconds When aView is off restart by pressing power button o...

Page 8: ...xternal monitor is displaying the correct input The external monitor shall be capable of receiving NTSC or PAL Toggle between NTSC and PAL in the video out menu on aView for best result The external m...

Page 9: ...n site before shipment to Ambu The cleaning and disinfection procedures explained in section 5 shall be followed Ambu reserve the right to return contaminated medical devices to the sender Guidance an...

Page 10: ...g der Ausstattung oder eine Abschirmung des genutzten Raums erforderlich Anweisungen zur Platzierung des aView finden Sie in den Tabellen in Anhang 1 12 Achten Sie darauf ob es sich beim angezeigten B...

Page 11: ...r die Composite Videoaus gangs Schnittstelle siehe Pos 6 PE PVC Abk rzungen PC Polycarbonat PE Polyethylen ABS Acrylnitril Butadien Styrol ZDC3 Zinklegierung PVC Polyvinylchlorid POM Polyoxymethylen...

Page 12: ...enn der Akkuladezustand sehr niedrig ist sind die Aufnahmefunktionen nicht verf gbar Falls der aView ausgeschaltet und der Akkuladezustand sehr niedrig ist blinkt die Einschalttas te alle zehn Sekunde...

Page 13: ...ischen Sie den aView anschlie end mit einer sterilen in gefiltertem Trinkwasser RO DI angefeuchteten Gaze ab Stellen Sie sicher dass alle R ckst nde des Reinigungs mittels entfernt wurden 7 Wiederhole...

Page 14: ...zstecker geerdet 4 Europ ische Konfiguration CEE 7 Netzstecker geerdet 5 D nische Konfiguration 2 5a Netzstecker geerdet 6 Konfiguration f r die Schweiz Typ J Netzstecker geerdet Weitere Informationen...

Page 15: ...on in der N he befindlichen elektro nischen Ger ten ist unwahrscheinlich HF Emissionen CISPR 11 Klasse B Das System ist f r die Verwendung in allen Einrichtungen geeignet einschlie lich solchen in h u...

Page 16: ...betragen Empfohlene Trennungsabst nde zwischen tragbaren und mobilen HF Kommunikationsger ten und dem System Das System ist f r den Betrieb in einer elektromagnetischen Umgebung bestimmt in der die H...

Page 17: ...Ambu A S Baltorpbakken 13 DK 2750 Ballerup Denmark T 45 72 25 20 00 F 45 72 25 20 50 www ambu com 492 4050 00 V01 2017 09 TCC 10368...

Reviews: