Format:
0xFF
0x10
0x00 < index > < CS >
Return:
0xFF
0x90
0x01 < status > < CS >
Status:
0x00: success
0x01: verification in flash failed
0x02: invalid index
7.11 CMD_FACTORYRESET_REQ
This command resets all parameters to their factory settings:
Format:
0xFF
0x11
0x00 0xEE
Return:
0xFF
0x90
0x01 < status > < CS >
Status:
0x00: success
After a factory reset the settings for the user interface are reset. These settings are only
activated after a restart of the module! Registered AES-Keys with their relating IDs are
retained.
7.12 Bidirectional communication
For this functionality also see chapter 9.
7.12.1 CMD_DATA_PRELOAD_REQ
With this command a telegram can be pre-loaded into the module.
This command generates two acknowledges:
1. Directly after the command has been sent to the module via serial interface
2. As soon as the pre-loaded telegram has been transmitted via radio, or from point of view
of the host at any arbitrary point of time.
Format:
0xFF
0x30
< number of bytes > < data with ALA-address of the counter > < CS >
Return:
0xFF
0xB0
0x01 < status > < CS >
Status:
0x00: success
0x01: telegram has been transmitted
0x02: no more memory available to preload a telegram