9.3.4 Lubricating the roller chain on the mechanical metering drive
INTERVAL
After the first 10 operating hours
Every 50 operating hours
or
at the end of the season
1. Remove the bolts
1
.
2. Remove the cover
2
.
CMS-I-00002724
3. Lubricate the roller chain
1
from the inside
going out.
4. Check chain tensioner
2
for ease of movement.
CMS-I-00003886
5. Install the cover
1
.
6. Install the bolts.
CMS-I-00002723
CMS-T-00005877-B.1
9 | Repairing the machine
Lubricating the roller chains
MG6967-EN-II | C.1 | 27.09.2021
222