7.
Route the connection cable
2
with the 6-pin
plug
1
to the interface of the hose package.
8.
Connect the 6-pin plug
1
to the interface of the
hose package.
1
2
CMS-I-00003744
6.3.12 Adjusting the low level sensor
1.
If low spread rates should be metered,
insert the low level sensor in the lower mount
2
.
2.
If high spread rates should be metered,
insert the low level sensor in the upper mount
1
.
NOTE
As soon as the low level sensor is no longer
covered, a warning message appears on the
control terminal.
When the low level sensor is inserted in the lower
mount, the warning message appears very late.
1
2
CMS-I-00003675
3.
Empty the hopper.
4.
Loosen the nuts on both sensor mounts
2
.
5.
Pull the low level sensor out of the mount
1
.
6.
Pull the sealing plug out of the desired mount.
7.
Insert the low level sensor flush in the desired
mount.
8.
Insert the sealing plug in the empty mount.
9.
Tighten the nuts on both sensor mounts.
1
2
3
CMS-I-00002513
CMS-T-00003330-B.1
6 | Preparing the machine
Preparing the implement for operation
MG6492-EN-II | G.1 | 26.04.2021
74