9.1.10 Checking the frame connection tightening torque
INTERVAL
After initial operation
Every 100 operating hours
or
as required
Depending on the implement equipment,
1.
check the tightening torque on the right-side
connection to the T-Pack F
1
.
2.
check the tightening torque on the left-side
connection to the T-Pack F
2
.
1
2
1
300 Nm
300 Nm
CMS-I-00003644
Depending on the implement equipment,
3.
check the tightening torque on the right lower link
mounting
1
.
4.
check the tightening torque on the left lower link
mounting
2
.
2
1
300 Nm
300 Nm
CMS-I-00003645
CMS-T-00003579-B.1
9 | Repairing the machine
Maintaining the machine
MG6492-EN-II | G.1 | 26.04.2021
113