Hydraulic hose lines must not be more than 6 years
old.
3.
Check the manufacturing date
1
.
CMS-I-00000532
4.
Have any worn, damaged or aged hydraulic
hose lines immediately replaced at a specialist
workshop.
5.
Retighten loose bolted connections.
9.1.4 Cleaning the conveyor section
INTERVAL
Every 50 operating hours
or
as required
The air drawn by the fan can contain fertiliser dust
or sand. These impurities can accumulate on the
fan rotors and cause imbalance of the fan. This can
destroy the fan.
REQUIREMENTS
The implement is coupled to the tractor
1.
Unlock the locks
4
.
2.
Open the calibration flaps
3
.
3.
Clean the suction cage
1
.
4.
To wash the deposits from the fan rotors
2
,
direct a jet of water into the suction opening.
1
2
3
4
CMS-I-00002509
CMS-T-00003327-B.1
9 | Repairing the machine
Maintaining the machine
MG6492-EN-II | G.1 | 26.04.2021
105