16
Solution Control Switch
The solution control switch will turn the pump on and
off. In order for solution to be delivered to the driver
assembly, the engine must be running and the solution
control switch must be on. Press the switch toward the
“I” and the pump will turn on. Press the switch toward
the “O” to turn the pump off.
Start
: Press the right side of the switch ( I ).
Stop
: Press the left side of the switch ( O ).
NOTE
: Do not operate the pump without solution in the
tank. This can damage the pump.
Solution Control Valve
The solution control valve is used to regulate the amount
of solution being applied to the floor. To increase the
flow of solution, turn the valve counter-clockwise. To
decrease the flow of solution, turn the valve clockwise.
The flow of solution can be completely shut off if the
valve knob is turned to far clockwise.
Increase
: Turn the valve counter-clockwise.
Decrease
: Turn the valve clockwise.
Stop
: Turn the valve all the way clockwise.
Solution Tank Drain Valve
Use the solution tank drain valve to remove remaining
solution. Remove the drain hose from the clip and
place in an appropriate container or drain. Opening the
valve, pushing downward, will drain the solution tank.
When draining is complete, close the drain valve and
reconnect hose using the hose clip.
Handle Adjustment
1. The height of the handle can be adjusted by raising
or lowering the handle.
2. Loosen the handle adjustment lever on the side of
the handle by turning is counter-clockwise (toward
the rear of the machine).
NOTE
: The handle adjustment lever will ratchet. Pull
outward and pivot the lever in the desired direction.
3. Move the handle to the desired height and tighten the
handle adjustment lever.