![background image](http://html.mh-extra.com/html/amano/mj-series/mj-series_operation-manual_2918179016.webp)
-12-
The lifting hooks on the unit may only be used for suspending the MJ unit. If a frame is placed below
the unit, it may not be suspended.
1)
A rubber vibration damper is placed between the MJ unit and the base at the bottom. This
rubber piece is supporting the unit. Therefore, if the lifting hooks on the unit are used to
suspend the unit with a frame attached to it, the attached frame could fall off.
2)
When a frame is attached to the unit, its center of gravity becomes high. If the unit is
suspended in this condition, it could lose balance and topple.
If you mount an optional frame with casters, use the casters only for moving. During operation, secure
the frame in place and take proper measures to prevent it from toppling.
Attach the duct hose to the inlet and secure firmly with a hose band, clamps, etc.
To prevent mist from accumulating inside, do not allow the duct hose at the inlet to droop down in the
middle of its routing. To minimize its suction resistance, keep the duct hose as short as possible.
Allow a space of 50 cm or more above the outlet hole.
Keep the operating ambient temperature between 5 and
40°C.
Keep the operating ambient humidity between 10 and 90%
(no condensation).
According to IEC-60664-1, the unit is rated at “pollution
degree 3”.
According to IEC-60664-1, the power supply is rated at
over voltage category III.
50cm min.
Lifting hook
Risk of frame falling
Risk of toppling
Base