![background image](http://html.mh-extra.com/html/amano/mj-series/mj-series_operation-manual_2918179022.webp)
-18-
2)
After passing the power cords through the cable
gland, tighten the cap at an appropriate length
and secure the power cords in place.
3)
Tighten the terminals at the end of the power
cords to the terminal block with screws.
Tighten the (green) ground wire securely to the
“E” ground terminal with a screw.
3
Cover the terminal box.
Put the cover on the terminal box and secure with
the screw.
IMPORTANT!
Static electricity discharged during the
operation can cause malfunction, faulty or
erroneous operation of the machine. So,
ensure the machine is correctly grounded
to enable the static electricity escape into
the ground.
CHECK!
Make sure that the grounding wires are
connected in conformity with “D-class
Grounding Work” requirements (grounding
resistance; less than 100 ohm).
CHECK!
Use round terminals for the tips of the
power cords. The diameter of the round
terminal should be M3.5, and the terminal
width should be 6.6 mm or less.
Power cord through here
Power cord conductors
Terminal width
6.6 mm max.
M3.5