-14-
Installing the Drain Hose
After finishing the installation, attach the drain hose. The drain port has 1-inch female threads. Place
the tip of the drain hose 100 mm or more in the oil. The length of the drain hose to the recovery
container should be 250 mm or longer.
NOTE:
When the collected mist accumulates inside the unit, its collection efficiency decreases. In addition,
the collected mist can blow out of the drain port. Therefore, be sure to attach a drain hose properly.
1
Attach the drain hose.
Attach the male-female elbow and the hose nipple to the drain port (1-inch female threads).
Then, attach the drain hose (ф 25mm bore) and secure it in place with the hose clamp.
2
Place drain hose in recovery container oil
the same oil as that in the collected mist into the oil pan and therein, sink the drain hose until
more than 100mm in length from its top end is submerged in oil. The length of the drain hose
from drain hole to oil surface of the drain pan should be more than 250mm.
During operation, vacuum (suction force) acts also on the drain port. In order to cancel out
the vacuum, a distance of 250 mm or longer is required between the hose and the recovery
container. The tip of the hose must be placed 100 mm or longer in the oil. Without its tip
being placed in the oil, the drain hose will draw in outside air instead of draining oil.
Supplied parts:
Male-female elbow, hose nipple, drain hose (2 m), hose band
Hose clamp
Male-female elbow
Hose nipple
Drain hose (
ф 25mm bore)
Oil pan
-
Inlet-side
-
Oil pan
(
m
in
)
(
m
in
)