![background image](http://html.mh-extra.com/html/amano/mj-series/mj-series_operation-manual_2918179028.webp)
-24-
5. Check whether air flow volume is recovered.
Resume operation and make sure of the recovery by putting a hand on
air outlet port. (At this time, never look into it. Otherwise, it may
result in an injury.)
•
Use tap water and compressed air within the following pressure range:
◆
Tap water: 0.2 to 0.5MPa
◆
Compressed air: 0.3 to 0.5MPa
•
The cleaning nozzle has
G
1/4
″
parallel pipe female thread. Use it
for reference when you use another cleaning kit than ours. Do not
start operation with this female threaded pipe being open.
Otherwise, oil leakage will be likely.
- Caution -
If drained oil is recycled to machining equipment, the tip of drain oil hose should be put in another
recovery bin to prevent inclusion of and dilution with tap water.
②
Cleaning using detergent
•
The collection disk is cleaned by spraying detergent on the
disk.
1. Stop operation.
If interlocked with machining equipment, stop it on the
utility side.
2. Open the inspection door.
Open either of doors on the side of main body.
3. Start operation and immediately stop it.
Once it started, stop it immediately.
4. Spray detergent aiming at the collection disk.
While the collection disk is rotating by inertia, spray
detergent upward on the collection disk more that 10 times
from the inspection door by using an atomizer. (The collection
disk can not be seen from the inspection door, but as far as
the disk is rotating, the mist of detergent will be absorbed on
the surface of the disk.) Warming the detergent up to about
50
℃
may improve the cleaning.
Recommended detergent:
Degreasing detergent - Amano
DEGREASER
(Product S/N: VF-4343)
When compressed air or water enters through the cleaning nozzle, the collection disc will start
rotating, and pick up speed gradually. Therefore, it is unnecessary to provide an additional
rotational movement.
Outlet hole
Knob bolts
Inspection
door
Detergent