Names Explained
Name
Purpose
Inlet
Draws oil mist by way of the rotational movement of the fan motor.
Cyclone
Separates and collects large cutting chips contained in the air stream that is
drawn in.
Collection disc
Collects the oil mist that spins along with the cyclone.
Inducer
Straightens the clean air that has passed the collection disc into a uniform flow.
Motor
Rotates the fan and the collection disc.
Fan
Rotates to generate suction in order to draw in the external air.
Exhaust muffler
Straightens and dissipates the clean air that is discharged from the fan in order
to reduce noise.
Outlet
Discharges clean air.
Roof
Covers the top of the unit.
Terminal box
Three-phase power supplied from the equipment circuit with a protective device,
connects here.
Lifting hooks
Used for lifting the unit.
Inspection door
The door for inspecting the cyclone. Open the two inspection doors on the side
to remove cutting chips or other deposits from the inside on a regular basis.
Inspection door knob
The knob keeps the door closed. Tighten it securely to prevent air leakage.
Drain port
Discharges the collected oil externally.
Cleaning nozzle
Nozzle for cleaning the collection disk. It cleans the collection disk by supplying
compressed air and tap water.