Appendix C - Using the Set Factory Defaults Utility
BreezeACCESS EZ AU-EZ
137
System Manual
The Set Factory Defaults utility is intended to enable management access to a
unit in cases where such access is not possible due to wrong or unknown
configuration of certain parameters. This includes cases such as unknown
Management VLAN ID and wrong management access filtering.
The utility accesses the unit by sending a special packet. Access to the unit is
based on its MAC address, which must be entered in the Unit MAC address field.
The set unit defaults feature is only available via the Ethernet port.
1
Connect the PC with the Set Factory Defaults utility to the Ethernet port of the
unit.
Enter the unit's MAC address.
2
Click on the
Set
button.
This utility performs the same operation as Set Complete Factory Defaults,
restoring the default factory configuration of all parameters, except to Passwords,
general FTP parameters and AU's Frequency.
To set factory defaults:
Figure C-1: Set Factory Defaults window