TR-3019-230E-ICU / TR-3019-400E-ICU
37
37
SETTING THE DOOR END POSITIONS
ACTION
SETUP OPERATIONS
3
Confirming
opening direction
Press
, then press
and hold them for at
least three seconds. When the LED makes quick
flashes (~5), release the buttons.
ATTENTION!
If the confirmation is not completed,
then when defining the direction of opening,
the
button was held for less than 2 s.
Repeat the definition of the opening direction!
4
OPEN end position With
move the door to the fully opened
position (LIMIT OPEN). To adjust the position use
as well
5
Confirming OPEN
Press
, then press
and hold them together
for at least 3 s. When the LED makes quick flashes
(~5), release the buttons
6
CLOSE end
position
With
move the door to the fully closed
position (LIMIT CLOSE). To adjust the position use
as well.
ATTENTION!
Door leaf lifting rope shall not be
eased off in the end position
7
Confirming CLOSE Press
, then press
and hold them for at
least 3 s. When the LED makes quick flashes (~5),
release the buttons
8
Exit setup
When the buttons are released, the standby mode
activates automatically
Y
ATTENTION!
After the setup perform several door open-close cycles using
and
. Make
sure that the door leaf moves in correct directions, stops in the end positions required accord-
ing to the door installation requirements. If the end positions need to be adjusted, repeat the
setup (
table
3).