TR-3019-230E-ICU / TR-3019-400E-ICU
31
31
PRODUCT DESCRIPTION
The kit includes the drive with integrated control unit, button control station and mounting kit.
The drive is equipped with an induction motor and a gear box (worm gear). Control of the door
final stop positions is performed by the drive’s encoder.
The drive can be set to one of three operation (control) modes:
• manual (manual operation mode is
ON
/
DIP1
switch,
table
4). The doors will move only
when the control element (button) is held. When delivered from the factory.
• pulse (manual mode is
OFF
). The doors movement to opening or closing, or stop of the
movement are performed by pressing the control button for a short period (pulse signal).
• automatic (manual mode is
OFF
and automatic closing in the settings is
ON
/
DIP6-8
switches,
table
4). A one-time pulse control signal will lead to a full cycle of doors
movement: ‘opening-countdown of set pause time till automatic closing-closing’.
Depending on the selected operation mode and the terms of use, the specialist determines
which control devices (key switch, remote control, etc.) and safe operation devices (safety mar-
gin, photocells) should be included into the drive system.
2.1
DELIVERY KIT
The delivery kit is shown in
Fig.
1.
Upon receipt of the product, check the completeness of the kit and make sure all the kit compo-
nents are free of visible damage. In case of any missing components, please, contact the supplier.
2.2
TECHNICAL SPECIFICATIONS
Table
1
PARAMETER
TR-3019-230E-ICU
TR-3019-400E-ICU
Rated-load torque, N∙m
30
Rated speed, rev / min
19
Maximum number of the output shaft revolutions
21
Maximum door leaf weight
*
, kg
145
Maximum door width
*
, m
6
Power supply voltage
230 V ± 10 % ~
400 V ± 10 % 3N~
Power frequency, Hz
50
Rated power consumption, W
400
450
Rated current, A
1.8
1.5
Maximum power consumption in standby mode without additional
devices, W
3.5
Electric motor
230 V ~
400 V 3 ~ / Y
Electric motor capacitor, uF
16
—
Thermal protection of electric motor, ° C
120
Maximum time of continuous operation, min
10
15
Maximum periodic activation period (mode)
**
25 % (S3)
40 % (S3)
Power supply of additional devices
12 V direct current / max 50 mA
24 V direct current / max 150 mA
* The data are given for certain types and sizes of ALUTECH industrial doors taking into account the drive characteristics and
the requirements of safety standards. Drive applicability and required safety devices are determined when placing an order.
** All specified characteristics are valid at an ambient tempe 20 ° C (± 5 ° C) and if the mounting and operation regulations
are complied with.