LEVIGATO DRIVES (LG SERIES)
|
LEVIGATO ANTRIEBE (SERIE LG)
|
COMMANDES LEVIGATO (SERIE LG)
13
GENERAL WARNINGS AND SAfETy RULES
Before installation, remove all unnecessary parts (cables, ropes, chains, etc.) and turn off all
unnecessary equipment, disconnect locking devices.
There should be sufficient space for the installation and operation of the drive system. Easy and
safe manual release of the drive rail should be provided.
Element of manual release design (cord) should be placed at a height of less than 1.8 m. Install
a sign with information about manual release (is included).
Stationary control devices should be located within sight of the doors, at a height not less than
1.5 m and at a distance from the moving elements. Control devices should not be publicly
available.
The drive can not be used for the doors, not equipped with a device to protect against the
falling of the door leaf.
The drive can not be used with doors with a built-in wicket door if the drive is not locked when
the wicket door is open.
When a mechanical locking bolt is installed on the doors ensure that the drive is locked when
the doors are locked.
If there is no wicket door within the door leaf or alternative means of access to the garage, in-
stallation of an emergency manual release device must be carried out (external lock to release
the drive rail / is ordered separately). Use an external manual release device only when the doors
are closed!
Please, make sure that the surface where the drive system is installed, is solid and can be used
as a reliable and rigid support. Otherwise, take measures to strengthen the installation places,
apply additional supports.
The socket must be installed in an accessible place so that the power cord (power cable) of the
drive is not located in the area of door movement and other moving parts. The electrical network
must be equipped with a protective earth. Please, make sure, that the section of the mains supply,
to which the drive is connected, is equipped with the short circuit protection device (Residual
Current Device (RCD) automatic switch or another equivalent device). The distance between the
terminals in the protection tripping unit should be at least 3 mm.
The electric cables of the control and safety devices should be laid separately from the cables with
mains voltage. The cables should be protected from contact with any rough and sharp surfaces
by using corrugated tubes, pipes and cable ducts to lay the cables. Use copper multicore cable
with double insulation for electric connection of the drive system components. The parameters
of the electric cables (section, number of wires, length etc.) should comply with the connection
diagram, device power, laying distance, way of laying, ambient conditions.
Check and, if necessary, adjust the drive for safe door operation (EN 12453), as incorrect ad-
justment may be dangerous. The correct and safe operation is set up by trained and qualified
specialists of the competent organization.
If necessary, the protection against compression, jamming, gripping, tightening and other
hazards should be provided: installation of safety devices; installation of protective designs
enclosing the zone of the door leaf movement; observance of safe distances and gaps between
the door leaf and fixed enclosing designs (EN 12604).
When operating out of sight of the doors or when the automatic door closing is activated,
photocells (or an equivalent safety device) must be installed.
Place a warning sticker (is included) in a conspicuous place or near to stationary control devices.