LEVIGATO DRIVES (LG SERIES)
|
LEVIGATO ANTRIEBE (SERIE LG)
|
COMMANDES LEVIGATO (SERIE LG)
31
TECHNICAL MAINTENANCE
• check that during closing when you stop the doors with both hands, the doors stop and
then open. During opening when you stop the doors with both hands, the doors stop.
Commissioning of the drive system can be done only after successful completion of tests. Partial
commissioning or temporary operation are forbidden.
Commissioning requires the installer to:
• prepare and keep technical documentation for the automation set. The documentation
shall include: general drawing, circuit layout, assembly and operation manual, as well as
maintenance schedule.
• pass the filled ‘Assembly and operation manual’ to the user (owner).
• prepare the ‘Maintenance schedule’ and give it to the user (owner).
Instruct about maintenance rules.
• instruct the owner about the existing hazards and risks, and inform about safe operation
rules. Explain to the owner the need to inform the persons operating the door about the
existing hazards and risks, and about safe operation rules.
8.
TECHNICAL MAINTENANCE
Perform scheduled maintenance of the drive system to ensure efficient and safe operation.
Scheduled maintenance shall strictly comply with the existing regulatory documents, instructions
in this manual, instructions for other involved devices, and following the safety rules. Perform
scheduled maintenance at least once every six months.
Scheduled maintenance shall include:
• read the section 1. ‘General warnings and safety rules’.
• check the wear of the set elements, paying attention to oxidization of the components.
Replace all parts and units with an unacceptable degree of wear. Use original parts from
the manufacturer.
• check the correctness of the door stop in its final positions. If necessary, reprogram the final
positions.
• clean external surfaces of the drive and safety devices. Clean with the help of a soft moist
cloth. The use of the following for cleaning is forbidden: water jets, high pressure cleaners,
acids and alkali.
• perform the check according to the instruction in section 7. ‘Testing and commissioning’.
9.
TROUBLESHOOTING
Y
ATTENTION!
In case of a failure, which cannot be repaired, based on the information
provided in this manual, consult the service department. Information about the service
department can be obtained from your supplier (vendor, installation company).
fAULT
POSSIBLE REASON
RECOMMENDATIONS
Drive does not work (ALUTECH
logo on the drive is not lit; display
does not react, when buttons on
the front plate are pressed)
No supply voltage or fuse
is blown
Check the supply voltage.
Check, and if necessary, replace
the fuse (fuse parameters should
comply with the marking)
Drive is not controlled by the
remote control (indicator on the
control is not lit)
Remote control code is not
recorded in the drive control
unit memory
Record the remote control in the
drive memory
Table 18