TECHNICAL MAINTENANCE
• check that du ring closing when you stop the doors with both hands, the doors stop and
then open. Du ring opening when you stop the doors with both hands, the doors stop.
Commissioning of the drive system can be done only after successful completion of tests. Partial
commissioning or temporary operation are forbidden.
Commissioning requires the installer to:
• prepare and keep technical documentation for the automation set. The documentation
shall include: general drawing, circuit layout, assembly and operation manual, as weil as
maintenance schedule.
• pass the filled 'Assembly and operation manual'to the user (owner).
• prepare the 'Maintenance schedule' and give it to the user (owner).
lnstruct about maintenance rules.
• instruct the owner about the existing hazards and risks, and inform about safe operation
rules. Explain to the owner the need to inform the persons operating the door about the
existing hazards and risks, and about safe operation rules.
8.
TECHNICAL MAINTENANCE
9.
&
Perform scheduled maintenance of the drive system to ensure efficient and safe operation.
Scheduled maintenance shall strictly comply with the existing regulatory documents, instructions
in this manual, instructions for other involved devices, and following the safety rules. Perform
scheduled maintenance at least once every six months.
Scheduled maintenance shall include:
• read the section 1. 'General warnings and safety rules'.
• check the wear of the set elements, paying attention to oxidization of the components.
Replace all parts and units with an unacceptable degree of wear. Use original parts from
the manufacturer.
• check the correctness of the door stop in its final positions. lf necessary, reprogram the final
positions.
• clean external surfaces of the drive and safety devices. Clean with the help of a soft moist
cloth. The use of the following for cleaning is forbidden: water jets, high pressure cleaners,
acids and alkali.
• perform the check according to the instruction in section 7. 'Testing and commissioning'.
TROUBLESHOOTING
ATTENTION!
In case of a failure, which cannot be repaired, based on the information
provided in this manual, consult the service department. Information about the service
department can be obtained from your supplier (vendor, installation company).
Drive does not work (the logo on
the drive is not lit; display does
not react, when buttons on the
front plate are pressed)
Drive is not control led by the
remote control (i ndicator on the
control is not lit)
..
No supply voltage or fuse
is blown
Remote control code is not
recorded in the drive control
unit memory
Tobte 18
Check the supply voltage.
Check, and if necessary, replace
the fuse (fuse parameters should
complywith the marking)
Record the remote control in the
drive memory
LEVIGATO DRIVES (LG SERIES) LEVIGATO ANTRIEBE (SERIE LG) COMMANDES LEVIGATO (SERIE LG)