CONTROL UNITS СU-TR230 / СU-TR400
109
109
SETTINGS
Table 1
4
VALUE
DESCRIPTION
01
Signal lamp.
The activation will occur during movement and during the delay time (
P8
–
F2
,
Table
13).
Figure
19 is an example of connecting a signal lamp
02
Lighting lamp.
The activation will occur during movement and during the time after the
movement stops (
P8
–
F3
,
Table
13). In the absence of movement, the lighting lamp can
be activated by a command from the radio remote control (control commands LIGHTING,
Table
4) with setting the response time (
P8
–
F4
, table 13).
Figure
19 is an example of connecting a lighting lamp.
03
Oneway traffic light (iscription of full opening).
Activation will accur after full opening.
Figure
20 is an example of connecting a traffic light.
04
No full closing.
Activation will always accur, except for full closing in standby mode.
Figure
21 is an example of connecting a traffic light using the second connector (second
relay) to turn off the traffic light (red light) when fully closing.
05
Traffic light on EXIT with twoway regulation.
Activation will accur after full opening by the
STEP BY STEP EXIT control commands and
OPEN EXIT
Y
ATTENTION!
With two-way
regulation, the specialist
determines the optimal control
scheme and requirements for
operational safety.
Figure
22,
Figure
23 are the examples of
connecting two traffic lights with two-
way regulation
06
Traffic light on ENTRY with twoway
regulation
.
Activation will accur after full
opening by the STEP BY STEP ENTRY control
commands and OPEN ENTRY
07
No full closing.
Activation will always accur, except for full closing in standby mode.
Figure
23 is an example of connecting two traffic lights using the third connector (third
relay) to turn off the traffic lights (red light) when fully closing
08
End position OPEN.
Actuation in the position of full opening
09
End position CLOSE.
Actuation in the position of full closing
10
Signal after the OPEN command.
Actuation 1 s after any OPEN control command
11
Signal after the CLOSE command.
Actuation 1 s after any CLOSE control command
12
Signal after control command.
Actuation 1 second after any control command (OPEN,
CLOSE, STOP, LIGHTING and others)
13
Load № 1.
The actuation will accur at the command of the radio remote control (control
commands LOAD №1,
Table
4) during the set response time (
P8
–
F7
, table 13)
14
Load № 2.
The actuation will accur at the command of the radio remote control (control
commands LOAD №2,
Table
4) during the set response time (
P8
–
F8
, table 13
15
Position PARTIALLY OPEN.
Actuation in the partial opening position after the control
command PARTIALLY OPEN
16
PHOTOTEST.
Actuation before the doors start to move after any control command CLOSE
during the operation verification of the safety device connected to input
PH1
(
Table
2,
connector 20).
Y
ATTENTION!
The PHOTOTEST function should be enabled in the settings (
P7
–
F3
,
table 13).
Figure
18 is an example of connecting photo rulers with a
TEST
contact for automatic
verification of operation