CONTROL UNITS СU-TR230 / СU-TR400
97
97
SETTINGS
Settings of menu
P2
:
F1
…
F3
— remote control command(s) record (
Table
5,
Table
6)
F4
,
F5
— changing the control command(s) of the recorded remote control (
Table
7,
Table
8)
F6
— determination of the remote control numbers (
Table
9)
F7
— determination of the recorded remote number (
Table
10)
F8
,
F9
— remote control deleting (
Table
10,
Table
11)
F0
— deleting all remotes (
Table
12)
Table
4 describes the radio control commands and the numbering of control commands is pre-
sented in menu
P2
.
Table 4
CONTROL COMMAND
SETTINGS
F1–F5
MEANING
NO COMMAND
Control command is not set
00
STEP BY STEP
(ENTRY)
Performing actions of opening, stopping movement,
closing. The sequence of actions is set by
setting
P3
–
F3
(
Table
13). When configuring the outputs
of connectors 7–9 (
Table
2) for two-way control operation
(settings
P3
–
F4
…
F6
,
Table
13), the ENTRY or EXIT
direction is determined
01
STEP BY STEP
(EXIT)
07
OPEN
(EXIT)
Performing of opening. When setting the outputs of
connectors 7–9 (
Table
2) for two-way control operation
(settings
P3
–
F4
…
F6
,
Table
13), the ENTRY or EXIT
direction is determined
02
OPEN
(ENTRY)
06
PARTIALLY OPEN
From the fully closed door position, the opening is
performed within the time set in
P1
–
F9
(
Table
13)
05
CLOSE
Performing of closing
03
STOP
Performing of movement stop
04
LIGHTING
(TURN ON)
Performing either TURN ON or TURN OFF, or TURN ON /
OFF when setting the outputs of connectors 7–9 (
Table
2)
for lighting operation (settings
P3
–
F4
…
F6
,
Table
13).
Automatic turn off (operating time) of lighting is set by
setting
P8
–
F4
08
LIGHTING
(TURN OFF)
09
LIGHTING
(TURN ON / OFF)
10
LOAD № 1
(TURN ON)
Performing either TURN ON or TURN OFF, or
TURN ON / OFF when setting the outputs of connectors
7–9 (
Table
2) to control external load №1 or №2 (settings
P3
–
F4
…
F6
,
Table
13). Automatic turn off (operating time)
of the load is set by the settings
P8
–
F7
(LOAD №1) and
P8
–
F8
(LOAD №2)
11
LOAD № 1
(TURN OFF)
12
LOAD № 1
(TURN ON / OFF)
13
LOAD № 2
(TURN ON)
14
LOAD № 2
(TURN OFF)
15
LOAD № 2
(TURN ON / OFF)
16