CONTROL UNITS СU-TR230 / СU-TR400
104
104
SETTINGS
MENU
SETTING
DESCRIPTION
VALUES
FACTORY
VALUE
P1
F7
*
Setting to disable the builtin obstacle detection system when opening
(
P5
–
F1
).
Designed to avoid false positives when using the built-in obstacle detection system
(
P5
–
F1
) in the unit when opening the doors. The position of the beginning of contact
of the damper (springs) of doors located at the end of opening is adjusted. From this
position until fully opening, the
P5
–
F1
setting will be disabled.
After entering the setting using
or
set the doors to the desired
position and press
to confirm the set position. The inscription
P
will appear
with a dot (
P.
) on the display
F9
Time of partially opening.
Opening is
performed from the end position of the closed
doors by the input command
P
(
Table
2,
connector 20) or by the command of the
remote control PARTIALLY OPEN (
Table
4).
no
— disabled
01
,
02
,
03 … 30
:
01
— 1 s
30
— 30 s
no.
P2
Radio control setting.
See section ‘6.2. Radio control setting’
P3
F1
Manual operation mode.
The movement
is performed by pressing and holding the
control device: only unit buttons
and
(
Figure
7),
and
(
Figure
8,
9) connection inputs
OP
and
CL
(
Table
2,
connector 20). To stop or block the start of
movement, only the unit buttons are active
and
, input
S
. The remote controls
do not work
no
— disabled
on
— enabled
on.
Y
In manual operation mode the control unit and other control devices must be located in a
place that provides a good overview of the door movement. In the case of access by unau-
thorized persons, control for them should be impossible, for example, by installing a switch
with a key (
Table
2, connector 17).
If manual operation mode is disabled, then mandatory use of safety devices (systems)
of
C
and
D
, or
E
type (EN 12453) is required. The selection of a solution (safety edge
and photocells, photo rulers or another) and execution of works (installation, setting,
verification) is carried out by qualified specialists of the competent organization.
F3
Collective mode of operation.
Depending on
whether the mode is on or off, the operation
logic of the
SBS
connection input (
Table
2,
connector 20) and the STEP BY STEP command
of the radio remote control differ (
Table
4).
Enabled:
with commands there
will be a sequence of operation
‘Open — Close — Open — Close
…
’. When
opening, the commands are not executed.
When closing, the command will cause a stop
of movement and subsequent full opening.
Disabled:
with commands
there will be a sequence of work
‘Open — Stop — Close — Stop — Open
…
’.
no
— disabled
on
— enabled
no.
* Only for control unit
CU-TR230
with
P1
–
F0
–
02
(for drive models with encoder). For drives with switches (
P1
–
F0
–
01
),
setting of the drive switch connected to the
P.L
input is required (
Figure
12).