![Alps Electric SPEEDGLIDER Operator'S Manual Download Page 49](http://html.mh-extra.com/html/alps-electric/speedglider/speedglider_operators-manual_2908782049.webp)
AIR LOGIC POWER SYSTEMS (ALPS)
CONTAINER CHANGE OVER
SPEEDGLIDER
ADVANCED OPERATOR MANUAL
48
TM 2012-005 REV00 © 10/25/2012
Container Change Over and Setup
This portion of the manual will discuss the necessary steps and procedures for changing over from one container
size to another.
Change Over Steps Overview
1. Carriage Slide Test Probe Adjustment
2. Railing Adjustment
3. Timing Screw Adjustment or Replacement
4. Timing Screw Acceleration and Deceleration Setup
Change Over Steps Guide
Step
Procedure Description
1. Adjust Carriage
Slide
A. Unlock clamp:
Left side: rotate handle clockwise to loosen,
Right side: Rotate handle clockwise to loosen.
B. The probe carriage can be raised or lowered to accommodate most container heights
by using the worm-gear crank that can only be accessed from the front. Turn clockwise
to raise, counter-clockwise to lower.
C. Place the container that will run on the SpeedGlider underneath a test probe. Raise or
lower the probe carriage to a level just ¼ inch above the top of the container opening.
Fine tuning can be controlled by viewing the scale located on the right side. The scale
is graduated in millimeters (mm). The example below denotes a height setting of
250mm.
D. Tighten Clamps clockwise
Left Manual
Clamp
device-
clockwise
to loosen;
counter -
clockwise
to tighten.
Right Manual Clamp
device-clockwise to
tighten; counter -
clockwise to loosen.
Left Manual
Clamp
device-
clockwise
to loosen;
counter -
clockwise
to tighten.
Right Manual Clamp
device-clockwise to
tighten; counter -
clockwise to loosen.