AIR LOGIC POWER SYSTEMS (ALPS)
THE SETTINGS MENU
SPEEDGLIDER
ADVANCED OPERATOR MANUAL
24
TM 2012-005 REV02 © 03/19/2013
Probe Take Off Navigation and Use
From the Home Screen select Settings Menu then select Probe Take-Off
3 and 4 Head Probe Alignment
Use the probe take off arrows to position and align the test
probes with the containers use the arrows on the display.
After adjusting the “Probe Take-Off” position and
the Test probes are properly centered ensure the container at test is
in the proper position.
Container at test Photo Eye Alignment
When the “Current Encoder Position” and the “Probe Take Off”
encoder values are equal the container must be aligned with the
Container at Test Photo-Eye. To check:
1. Place a container in the timing screw slot near the Container at
Test Photo Eye.
2. Rotate the timing screw until the “Probe Take Off” value and
the “Current Encoder Position” value are equal.
3. If necessary adjust the photo-eye so it is in the center of the
largest and flattest section of the bottle.
At any time
select the Information button to access helpful information on the current menu display. The
help screens for Probe Take-Off.