21
Subject to change without notice.
83054800bUK – Translation into English of the original German operating manual ait-deutschland GmbH Subject to change without notice.
Subject to change without notice.
83054800bUK – Translation into English of the original German operating manual ait-deutschland GmbH
Insulating the hydraulic
connections
Insulate the vibration isolators and the fixed piping of the
heating circuit.
NOTE.
Insulate according to the relevant local standards,
guidelines and directives.
Installing the control unit
DANGER!
There are 4 openings each at different
heights in the front panel of the unit for
fastening the control unit:
1 four upper openings
2 four lower openings
There are 4 hooks at the rear of the control unit, which are
used to hook the control unit onto the front panel of the
unit:
Hook the control unit's hooks into the openings of the
front panel (either in the upper or lower openings)…
Example: Control unit in upper openings
Press the hooked in control unit downwards until it
latches into position…
Push the control cable of the heating and heat pump
controller into the
right
socket on the underside of
the control unit…
NOTE.
A connection to a computer or a network can be
made via the left socket on the underside of the
control unit, in order to enable the heating and
heat pump controller to be controlled remotely
from there. This requires a shielded network cable
(category 6) to have been laid through the unit
during the electrical connection work.