OPERATION
Continued from the previous page.
1.5 “Doctor mode” function (automatic door opening):
Descrip
:
tion
The “doctor mode” function allows lock release 1 to activate automatically 6 seconds after making a call from the door
panel without having to establish communication or pressing door release push button
. The main monitor will
display the door panel image without alerting the visitor. The call ends after 40 seconds and the channel is freed.
10
VESTA2 G 2 MONITOR
B
Enabling “doctor mode”:
To enable doctor mode, enter function code [9018] in the installer setup (see pages 24 and 25).
Activating “doctor mode”:
To activate doctor mode, the monitor must be in standby mode. Then press push button
for 10 seconds. Status
LED
will blink to indicate that the doctor mode function is activated.
Deactivating “doctor mode”:
To deactivate doctor mode, the monitor must be in standby mode. Then press push button
for 10 seconds. Status
LED
will turn off to indicate that the doctor mode function is deactivated.
Important:
When activating “Do not disturb” mode (with the monitor's “doctor mode” activated), the status LED will change from
blinking to #xed and the “doctor mode” function will be cancelled.
When deactivating “Do not disturb” mode (with the monitor's “doctor mode” activated), the status LED will blink and the
“doctor mode” function will be reactivated.
Installer setup
[ ]
9018