Chapter 4: Redundancy
NetEnforcer AC-2500 Hardware Guide
4-11
Standby
LED
Active
LED
Power
LED
Analysis
Primary
Unit
OFF
OFF
ON
Primary NetEnforcer failed or not
completed booting.
Secondary
Unit
OFF
OFF
ON
Secondary NetEnforcer failed or not
completed booting. Bypass is activated
(in the primary unit and all traffic is
going through Bypass.
Table
4-1 – LED Conditions: AC-2500 Series, Parallel Redundancy Mode
Secondary NetEnforcer Activation
When two NetEnforcers are connected in Parallel Redundancy mode, the Secondary
NetEnforcer will take control and become the active unit under the following
conditions:
•
Upon a Primary subsystem failure.
•
During booting of the Primary NetEnforcer platform. When booting is
completed, the Primary unit automatically takes control again.
•
Upon any Primary NetEnforcer power feed failure and power OFF condition.
•
Upon the Primary NetEnforcer Ethernet cable disconnecting from either the
Internal or External ports. After reconnecting the cable and rebooting, the
Primary NetEnforcer takes control again.
•
When the Bypass Unit is not connected properly to the NetEnforcer Backup
connector, even with all other connectors fully plugged.
NOTE
If a cable is disconnected, it is recommended to reboot the Primary
NetEnforcer after reconnecting the cable.