ALL126AS3
USER’S MANUAL
10
2.3 General Rules
Before making any connections to the router, please note the following rules:
Ethernet Port (RJ-45)
All network connections to the router Ethernet port must be made using Category 5 UTP/STP or above for
100 Mbps, Category 3, 4 UTP for 10Mbps.
No more than 100 meters of cabling may be use between the MUX or HUB and an end node.
VDSL2 Port (RJ-11)
All network connections to the RJ-11port must use
24~26
gauge with
twisted pair
phone wiring.
We
do not recommend
the use of the telephone line 28 gauge or above.
The RJ-11 connectors have six positions, two of which are wired. The router uses the center two pins. The
pin out assignment for these connectors is presented below.
Please note that the line port is no polarity, therefore user can reverse the two wires of the phone cable
when installed.
RJ-11 Pin out Assignments
Pin#
MNEMONIC
FUNCTION
1
NC
Unused
2
NC
Unused
3
DSL
Used
4
DSL
Used
5
NC
Unused
6
NC
Unused_