QUICK
REFERENCE GUIDE
Tableau Forensic T35u/T35u-RW SATA/IDE Bridge
GETTING STARTED
Confirm that the bridge is off before beginning.
1. Connect either an IDE source drive , or a SATA source drive to the
right side of T35u/T35u-RW
2. Connect the bridge to the host computer using the host USB port
3. Connect the power supply to the bridge’s DC In
4. Press the power button and begin operation
Before you remove the connected SATA/IDE drive or power down the
T35u/T35u-RW, safely eject or unmount the drive on your host computer.
CONNECTION RECOMMENDATIONS
For SATA Drive
Use a Tableau SATA Drive Power cable (TC5-8-R2)
& SATA Data cable (TC3-8)
For IDE Drive
Use a Tableau IDE Drive cable (TC2-8-R2) & IDE
Data cable (TC6-8)
For the Host Connection
Use a Tableau USB 3.0 cable (TC-USB3)
For Power (DC In)
Use a Tableau power supply (TP5 or TP2)
DIP SWITCH SETTINGS
SWITCH 1
ON = Read/Write
OFF = Read-Only
SWITCH 2
ON = Hide Write Protect
OFF = Report Write Protect
SWITCH 3
ON = Hide Write Errors
OFF = Report Write Errors
SWITCH 4
No Function
* Default setting is OFF for all switches
Power
IDE Detect
SATA Detect
Host Detect
Write Bock
Activity
Tableau Forensic
SATA/IDE Bridge
DC IN
USB 3.0
IDE
DC
OUT
SATA
Update Mode
Locate breakaway
plastic & remove
Adjust DIP switches
for intended use