Bonito Technical Manual
V2.4.0
45
Parameters and commands
Related
Parameters
A
,
B
,
D
, and
N
Example
I=4
output every 4
th
line
N=1AF
(0x1AF = 431), sets number of lines to 431, which equals a quarter
of the full image
Synchronization output (J)
Parameter
J
sends an output synchronization signal to pin 6 of the camera con-
trol connector.
Valid values
Either one of the values
0
,
1
,
2
,
3
,
8
,
9
,
A
,
B
Default
1
Related
Parameters
D
,
E
,
F
,
M
,
N
and
S
Setting
Output signal
J=0
Effective sensor exposure
J=1
Charge transfer pulse
Active for one line duration at the end of exposure. End of this
pulse marks the end of exposure and at the same time start of sen-
sor readout.
In PIV mode: this pulse occurs at the exposure end of only the first
image of each PIV pair. For more information see chapter
J=2
Effective sensor readout
J=3
Exposure phase
Contrary to
J=0
, this setting shows the exposure phase of the
internal state machine and not the effective exposure of the sen-
sor. This allows to synchronize external devices even if the sensor
is in permanent exposure mode. For more details see chapter
J=8
Same as
J=0
, but with inverted logic on sync output
J=9
Same as
J=1
, but with inverted logic on sync output
J=A
Same as
J=2
, but with inverted logic on sync output
J=B
Same as
J=3
, but with inverted logic on sync output
Table 7: Synchronization output