Bonito Technical Manual
V2.4.0
50
Parameters and commands
The next falling edge stops the exposure and starts the output of the image syn-
chronized to the next line.
Due to the line jitter the next rising edge of the trigger should not appear earlier
than t
FDmin
+ t
L
after the previous rising edge.
Image on demand mode (IOD) with exposure timer
Bit group: e
Value: 2
The exposure time is controlled by the parameter
E
.
Each rising edge of an externally applied signal starts one exposure. Use param-
eter
T
to select the signal source.
A rising edge at the corresponding input starts exposure synchronized to the
line after the next.
The next rising edge must not arrive earlier than
t
FDmin
+ t
L
or
Figure 24: Exposure timing mode, M=1, flow diagram
Parameter
Value
Trigger Period
t
TP
> t
FDmin
+ t
L
Trigger High Duration
t
L
< t
TH
< t
TP
– t
L
Exposure Jitter
0 < t
j
< t
L
Exposure Time
t
Exp
= t
TH
– t
L
± t
j
Table 13: Exposure timing mode,
M=1, timing parameters