Bonito Technical Manual
V2.4.0
37
Camera Link interface (01-04 or
Dual channel, full line length
The charts below illustrate the Camera Link timing for dual channel mode (full
line length,
S=1
), in continuous mode (
M=0
). The frame gap may vary in other
trigger modes. Additionally, the number of active lines per frame can be config-
ured by the user (parameter
N
).
Note
The diagrams displayed are not applicable for the
Bonito CL-
400B/C 200fps
cameras.
Figure 19: Line timing for dual channel mode (full line length,
S=1)
Figure 20: Frame timing for dual channel mode (full line length,
S=1
)