Bonito Technical Manual
V2.4.0
63
Parameters and commands
Trigger source selection (T)
This parameter selects the signal source for triggering and exposure control.
For more information about usage of the selected signals: see chapter
Range
Either
0
,
2
,
3
, or
4
Default
3
Related
Parameter
M
Example
T=2
Select the optocoupler input at pins 10 and 11 of the I/O connector
as trigger source
S=5
Same as
S=1
, but with right image half via O2/O1 and left image
half via O4/O3 (if available).
S=7
Same as
S=3
, but with right image half via O2/O1 and left image
half via O4/O3 (if available).
(Others)
Reserved for future use.
Setting
Function
T=0
No input selected.
T=2
Optocoupler OK1 at pins 10 and 11 of the control connector.
T=3
CC1 at the Camera Link connector O2 or CL1 (default).
T=4
CC1 at the Camera Link connector O4.
(Others)
Reserved for future use.
Table 24: Trigger source selection (T)
Note
For more information:
see chapter
Setting
Function
Table 23: Camera Link output settings.