Bonito Technical Manual
V2.4.0
51
Parameters and commands
E * t
TR
+ t
L,
whichever is the bigger, after the previous rising edge.
Image on demand mode (IOD) with exposure timer and frame
duration timer
Bit group: e
Value: 3
This mode is also free-running (like
M=0
), but exposure time and frame duration
is set accordingly, using the parameters
E
and
F
. Furthermore, the start of the
exposure may optionally be synchronized to the rising edge of an externally
applied synchronization pulse. Use parameter
T
to select the synchronization
signal source. If any synchronization event takes place during exposure, the cur-
rent frame may be exposed abnormally.
Figure 25: Exposure timing mode, M=2, flow diagram
Parameter
Value
Trigger Period
t
TP
> max (t
FDmin
, E * t
TR
) + t
L
Trigger High Duration
t
L
< t
TH
< t
TP
– t
L
Exposure Jitter
0 < t
j
< t
L
Exposure Time
t
Exp
= E * t
TR
– t
L
± t
j
Table 14: Exposure timing mode, M=2, timing parameters