Pike
Technical
Manual
V5.2.3
176
Controlling image capture
Controlling
image
capture
Register
Name
Field
Bit
Description
0xF0F00830 TRIGGER_MODE Presence_Inq
[0]
Presence
of
this
feature:
0:
N/A
1:
Available
Abs_Control
[1]
Absolute
value
control
O:
Control
with
value
in
the
Value
field
1:
Control
with
value
in
the
Absolute
value
CSR
If
this
bit
=
1
the
value
in
the
Value
field
has
to
be
ignored
---
[2
to
5]
Reserved
ON_OFF
[6]
Write:
ON
or
OFF
this
feature
Read:
read
a
status
0:
OFF
1:
ON
In
this
bit
=
0,
other
fields
will
be
read
only.
Trigger_Polarity [7]
Select
trigger
polarity
(Except
for
software
trigger)
If
Polarity_Inq
is
1:
Write
to
change
polarity
of
the
trigger
input.
Read
to
get
polarity
of
the
trigger
input.
If
Polarity_Inq
is
0:
Read
only.
0:
Low
active
input
1:
High
active
input
Trigger_Source
[8
to
10] Select
trigger
source
Set
trigger
source
ID
from
trigger
source
ID_Inq
Trigger_Value
[11]
Trigger
input
raw
signal
value
read
only
0:
Low
1:
High
Trigger_Mode
[12
to
15] Trigger_Mode
(Trigger_Mode_0..15)
---
[16
to
19] Reserved
Parameter
[20
to
31] Parameter
for
trigger
function,
if
required
(optional)
Table 67: Trigger_Mode_15 (Bulk Trigger)