Pike
Technical
Manual
V5.2.3
335
Configuration of the camera
Configuration
of
the
camera
User adjustable gain references
This
register
gives
the
user
the
possibility
(via
direct
access)
to
modify
the
gain
references.
Modified
values
are
stored
automatically
without
further
user
action
and
are
also
stored
on
restart.
To
reload
default
gain
references
(which
are
programmed
at
personalization)
within
the
camera:
set
flag
m_bDefGainRef=1
In
the
following
table
you
find
the
default
gain
references
of
all
Pike
models.
*:
Firmware
package
version
00.03.00.01
or
earlier
Offset
Name
Field
Bit
Description
0xF1002000
AFEREFERENCES
Presence_Inq
[0]
Indicates
presence
of
this
feature
(read
only)
---
[1
to
4]
Reserved
m_bDefGainRef
[5]
Reload
default
gain
references,
if
this
flag
is
set.
---
[6
to
31]
Reserved
0xF1002004
GAINREFERENCE
m_GainRef
[0
to
31]
Gain
reference
(0
to
511)
Table 201: Advanced register: User adjustable gain references
Model
Default gain reference (decimal)
Default gain reference (hex)
Pike
F-032B,
F-032C
200
C8h
Pike
F-100B,
F-100C
210
D2h
Pike
F-145B,
F-145C
(15fps) 30
(15*)
1Eh
(0Fh*)
Pike
F-145B,
F-145C
(30fps) 85
(15*)
55h
(0Fh*)
Pike
F-210B
215
D7h
Pike
F-421B,
F-421C
200
C8h
Pike
F-505B,
F-505C
205
(130*)
CDh
(82h*)
Pike
F-1100B,
F-1100C
228
E4h
Pike
F-1600B,
F-1600C
193
C1h
Table 202: Default gain references of Pike models