Camera interfaces
MARLIN Technical Manual
V2.4.0
56
Outputs
T
Output features are configured by software. Any signal can be placed on any
output.
The main features of output signals are described below:
Note
L
•
Switching trigger delay to ON also switches external
Trigger_Mode_0 to ON.
•
This feature works with external Trigger_Mode_0 only.
Note
L
For a general description of the
outputs
and
warnings
see
the
Hardware Installation Guide
, Chapter
MARLIN output
description
.
Signal
Description
IntEna (Integration Enable) signal
This signal displays the time in which exposure
was made. By using a register this output can be
delayed by up to 1.05 seconds. This signal can be
used to fire a
strobe flash.
Fval (Frame valid) signal
This feature signals readout from the sensor. This
signal Fval follows IntEna.
Busy signal
This signal appears when:
•
the exposure is being made or
•
the sensor is being read out or
•
data transmission is active.
The camera is busy.
Table 23: Output signals