Advanced register: frame counter
The
frame counter
feature is controlled by the following advanced feature
register:
Having this feature enabled, the current
frame counter
value (images read
out of the sensor, equivalent to # FrameValid) will be inserted as a 32-bit
integer value into any captured image.
Setting the
Reset
flag to 1 resets the frame counter to 0 — the
Reset
flag
is self-cleared.
The
ON_OFF
and
LinePos
fields are simply mirrors of the time stamp feature.
Settings of these fields are applied to all image stamp features.
Additionally there is a register for direct read out of the frame counter value.
Register
Name
Field
Bit
Description
0xF1000610 FRMCNT_STAMP
Presence_Inq
[0]
Indicates presence of this
feature (read only)
Reset
[1]
Reset frame counter
---
[2..5]
Reserved
ON_OFF
[6]
SIS (time stamp) on/off
---
[7]
Reserved
---
[8..15]
Reserved
LinePos
[16..31]
Line position of SIS (time
stamp)
0xF1000614 FRMCNT
[0..31]
Frame counter
Table 126: Advanced register: