Chapter 2: Managing Switch
122
RMON Alarm
The RMON Alarm page allows you to configure RMON statistics group
and alarm groups.
To access this page, click
Management
>
RMON
>
RMON Alarm
.
Figure 108. Management > RMON > Rmon Alarm
The following table describes the items in Figure 108.
The
Alarm Information
settings in the ensuing table are informational
only: Index, Interval, Variable, Sample Type, Rising Threshold, Falling
Threshold, Rising Event Index, Falling Event Index, Owner and
Delete
(click to delete the desired index).
Table 104. Rmon Alarm
Item
Description
Index
Enter the index entry (1 to 65535) to define a specific Alarm Collection
history entry.
Interval
Enter a value (1 to 2147483647) to define the interval value for the
Alarm Collection history.
Variable
Enter the alarm variables to define the monitoring triggers.
Sample Type
Enter the variable sample type.
Rising Threshold
Enter the rising alarm threshold trigger.
Falling Threshold
Enter the falling alarm threshold trigger.
Rising Event Index
Enter the rising event index (1-65535) to define the alarm group.
Falling Event Index
Enter the falling event index (1-65535) to define the alarm group.
Owner
Enter the name of the owner of the RMON alarm group.
Apply
Click
Apply
to save the values and update the screen.