38
53277
Section 4 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
44. HEAT SHIELD
a. On Gas Models up to Serial No. D934952,
remove burner housing and heat shroud. Refer
to Paragraphs 26 and 27.
b. On Gas Models starting with Serial No.
D934953, remove two screws from vent at rear
of machine and remove vent.
c. On Electric Models, remove heating element.
Refer to Paragraph 28.
d. Remove screws holding bottom end of heater
box to heat shield. Refer to Figure 33.
e. Disconnect vent, electric power and gas supply
line (if present) and move dryer to gain access
to rear of unit.
f. Remove screws holding heat shield to rear of
dryer cabinet. Refer to Figure 36.
45. REAR MOUNTING BRACKETS
a. Remove rear bulkhead and heater box. Refer to
b. Remove screws holding rear mounting brackets
to rear of cabinet. Refer to Figure 36.
46. CABINET AND BASE
a. Remove front panel. Refer to Paragraph 11.
b. Remove front bulkhead assembly. Refer to
c. Remove motor and exhaust assembly. Refer to
d. Remove cylinder assembly. Refer to Paragraph
40.
e. Remove rear bulkhead and heater box. Refer to
f. Remove heat shield. Refer to Paragraph 44.
g. Remove two hex head screws from front edge
of each side of cabinet. Refer to Figure 28.
h. On upper cabinet, remove remaining screws
around bottom edge of cabinet and lift cabinet
off center section.
i. On lower cabinet, remove center section,
remove remaining screws around bottom edge
of cabinet and lift cabinet off base.
Figure 36
DRY867S
GROUND
SCREW
MOUNTING BRACKET
ATTACHING SCREWS
HEAT
SHIELD
ATTACHING
SCREWS
EXHAUST
DUCT