53277
43
Section 6 Gas Burner Conversion Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
i. Sign and date each of the two No. 60518 L.P.
Gas Stickers. Install one of the No. 60518 L.P.
Gas Stickers over the top three lines of the old
sticker on rear of cabinet. Refer to Figure 41.
Then place the second sticker over the top three
lines of the old sticker located on backside of
access door. Refer to Figure 38.
j. Apply the No. 60513 Conversion Plate to the
inside of the loading door opening above the
nameplate. Refer to Figure 42.
k. Connect electrical service and turn the gas line
shut-off valve handle to the open position.
Refer to Figure 40.
l. Check gas valve pressure as follows:
(1) Remove pressure tap pipe plug. Refer to
(2) Connect a “U” tube manometer (or similar
pressure gauge) to the pressure tap. Refer
to Figure 43.
(3) Start dryer. Pressure should be 10 ± 1.5
inches. Refer to Figure 43.
Figure 41
DRY964S
APPLY NO. 60518
L.P. GAS
STICKER HERE
Figure 42
Figure 43
DRY912P
APPLY
CONVERSION
PLATE HERE
NAMEPLATE
DRY965S
MANOMETER
10 ± 1.5
INCHES
AIR
SHUTTER
GAS VALVE
PRESSURE TAP
AIR SHUTTER
LOCKSCREW