TO REMOVE FRONT CYLINDER SEAL
d. Unhook spring from seal strap. Refer to
NOTE: Old sealant must be removed from flanged
area before reinstalling felt seal. Seal must be held
securely under strap and folded under flanged edge
around entire bulkhead. Strap must be installed
with cupped surface down against the seal to hold
the felt seal more firmly in place on the bulkhead.
The seal can also be adhered to the bulkhead using
3M-1300
®
Sealant (obtain locally). This is
accomplished by apply a bead of 3M-1300
®
Sealant
around the entire flanged area where the felt seal
contacts the bulkhead.
39. CYLINDER BELT
a. Remove front panel. Refer to Paragraph 11.
b. Disengage belt from motor and idler pulleys.
c. While supporting cylinder, carefully remove
belt off cylinder.
NOTE: When reassembling, belt must be properly
positioned around cylinder and on motor and idlers
pulleys. Refer to Figure 30. Place belt halfway
between middle screw and back screw that holds
baffles to cylinder. Check belt installation by
rotating cylinder counterclockwise.
Figure 29
DRY861S
FELT
SEAL
SEAL STRAP
(Installed with
cupped surface
against seal)
BULKHEAD
SPRING
CYLINDER GLIDE
ATTACHING SCREWS
Seal must be
positioned under
flanged edge
Figure 30
DRY862S
BELT
IDLER
PULLEY
MOTOR
PULLEY