Section 4 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
37. MOTOR AND IDLER PULLEY
ASSEMBLIES
a. Remove motor and exhaust assembly. Refer to
b. Refer to Figure 25 for motor and idler pulley
removal.
38. FRONT BULKHEAD ASSEMBLY
a. Remove front panel, Paragraph 11.
b. Remove four screws holding bulkhead to
cabinet and lift assembly out of slots in cabinet.
Refer to Figure 28.
c. Disconnect belt.
NOTE: Front air duct will be removed with the
bulkhead unless previously removed in Paragraph
31.
Figure 27
DRY956S
2
1
6
4
5
2
1
6
5
4
MOTOR SWITCH
DRIVE
MOTOR
GROUND
WIRE
Figure 28
DRY858S
HEX HEAD
SCREWS
SLOT
CABINET
ATTACHING
SCREWS