Section 6 Gas Burner Conversion Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
(4) Stop dryer and remove “U” tube and
reinstall the pressure tap pipe plug. Refer to
Figure 40.
m. Check the gas line connection for gas leaks with
a soapy solution.
n. Make sure the dryer conversion has been
completed. Recheck the following:
(1) Installed correct orifice spud (#53), refer to
Step “e”.
(2) Installed the block-open plug. Refer to Step
“g”.
(3) Gas valve pressure must be 10 ± 1.5 inches.
Refer to Step “l”.
(4) Install four stickers. Refer to Steps “h”, “i”
and “j”.
o. Start dryer and observe burner flame. Adjust air
shutter to obtain a soft, uniform flame. (A lazy,
orange tipped flame indicates lack of air. A
harsh, roaring, very blue flame indicates too
much air.) Adjust air shutter to obtain a soft
uniform blue flame as follows:
(1) Loosen air shutter lockscrew.
(2) Turn air shutter to the right or left as
necessary to obtain proper flame intensity.
Refer to Figure 43.
(3) After air shutter is adjusted for proper
flame, tighten air shutter lockscrew
securely.
p. Be sure and observe at least two complete
ignition and burn cycles before reinstalling
access door.
q. Reinstall access door and screw.
To reduce the risk of explosion and fire, do
not use an open flame to check for gas
leaks!
WARNING