40
53277
Section 5 Adjustments
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
48. BURNER FLAME (Gas Models)
a. Remove Phillips head screw and washer
holding the access door to the front panel. Refer
to Figure 38.
b. Apply thumb pressure to the right edge of the
door. When the door opens, move the door to
the left to disengage from the door supports.
Refer to Figure 38.
c. Set FABRIC switch at NORMAL.
d. Close the loading door, start the dryer in a heat
setting (refer to the Operating Instructions
supplied with the dryer); the dryer will start, the
igniter will glow red and the main burner will
ignite.
e. Allow the dryer to operate for approximately
five minutes, then open the access door and
loosen the air shutter lockscrew.
f. Turn the air shutter to the left or right to obtain
a soft, uniform blue flame. (A lazy, orange-
tipped flame indicates lack of air. A harsh,
roaring, very blue flame indicates too much
air.)
g. After proper flame is obtained, tighten air
shutter lockscrew securely.
Figure 38
DRY951S
WASHER
PHILLIPS
HEAD
SCREW
APPLY
PRESSURE
HERE
SUPPORT
ACCESS
DOOR