34. MOTOR AND EXHAUST ASSEMBLY
Refer to Figure 25
a. Remove front panel. Refer to Paragraph 11.
b. Remove front air duct. Refer to Paragraph 31.
c. Disconnect wires from thermostats or
thermostat heater and thermostat.
NOTE: Refer to appropriate wiring diagram when
rewiring thermostats.
d. Remove cylinder belt from idler and motor
pulleys.
e. Remove two (2) screws holding motor
mounting bracket to base and pull entire
assembly out through front of dryer.
NOTE: When removing motor and exhaust
assembly, it may be necessary to remove wire clips
from right side of cabinet to provide clearance.
f. Disconnect wires from motor switch.
NOTE: Refer to appropriate wiring diagram when
rewiring motor.
IMPORTANT: When reinstalling motor and
exhaust assembly, be sure wire harness on right side
is clipped to motor mount and is routed along base,
between motor mounting bracket and right side of
cabinet. Refer to Figure 24. Tab on rear of motor
mounting bracket must be positioned in slot
provided in base. Exhaust duct MUST BE
reinstalled on flange of exhaust housing.
Figure 24
DRY953S
MOTOR MOUNT
ATTACHING SCREWS
COVER
ATTACHING
SCREWS
(3)
EXHAUST
FAN COVER
FELT
SEAL
TAPE
WIRE